SKU: 11839893191

Rat ENO1 ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 10 - Jul 15

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Rat ENO1 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)

2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL

3. 37℃ constant temperature box

4. Distilled water or deionized water

Sample processing and requirements:
Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.

Plasma: Collect specimens using EDTA or heparin as anticoagulants and centrifuge them at 1000×g for 15 minutes at 2-8℃ within 30 minutes of collection. The supernatant can be tested or stored at -20℃ or -80℃, but repeated freezing and thawing should be avoided.

Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.

2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL.

Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details.

3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use.

4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.

5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.

2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes.

(Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)

3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.

4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).

5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.

6. Washing: Discard the liquid and wash the plate five times as in step 4.

7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.

8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.

2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with an alpha-enolase (ENO1) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of alpha-enolase (ENO1) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Rat
Synonym Rat Alpha-enolase  ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Non-neuronal enolase (NNE), also known as enolase 1 (ENO1) or α-enolase, is a glycolytic enzyme expressed in most tissues and one of the enolase isozymes. Each isozyme is a homodimer composed of two α, two γ, or two β subunits and functions as a glycolytic enzyme. In addition, α-enolase, as a monomer, functions as a structural crystallin. Alternative splicing of this gene results in a shorter isoform that has been shown to bind to the c-Myc promoter and act as a tumor suppressor.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.312-20 ng/mL
Applications Serum, plasma, and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 11839893191

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.1 ★★★★★
Based on 1333 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
M
Verified Purchase
MLG
Charlottesville, US
★★★★★ 4
Sudsy!
Size: Small
I was looking for an organic body scrubber that created lots of suds and was easy to dry without getting moldy. The Cleanlogic body scrubbers fit the bill. I deducted a star because although they are organic, easy to hang dry, create lots of suds and thoroughly exfoliated my body, they’re expensive, in my opinion. I’ve tried different brands and different kinds of scrubbers- natural loofahs, silicone hand exfoliators, body wash cloths- they all had their own shortcomings. The Cleanlogic has been one of my favorite body tools but I haven’t decided if it’s worth the cost of adding to my subscription or buying them on occasion when I want to splurge.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 3, 2026
A
Verified Purchase
Amazon Customer
Lexington, US
★★★★★ 5
Perfect cartridges for my Dr. Pen M8 – sterile, secure, and seamless fit
I've been using these replacement cartridges with my Dr. Pen M8 for a couple weeks now, and they're a standout. First off, the packaging is top-notch – everything arrived tightly sealed with no damage, which is crucial for sterile medical-grade supplies like these. No leaks, no mess, just clean and professional presentation right out of the box. What really sets these apart is how flawlessly they integrate with the Dr. Pen M8. They snap in effortlessly with a secure lock, no wobbling or compatibility issues during sessions. The single-use design suspended in individual sterile packaging gives real peace of mind – I can tell they're fresh and uncontaminated every time, which is non-negotiable for at-home microneedling. Pros: Excellent sterile suspension packaging prevents contamination Perfect fit and function with Dr. Pen M8 High-quality build feels reliable for multiple uses No real cons here – these cartridges perform consistently and make the whole process smoother. If you're running a Dr. Pen M8, these are a smart, hassle-free choice that delivers on hygiene and performance. Highly recommend for anyone serious about clean, effective treatments
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 24, 2026
T
Verified Purchase
Taylor Ashley
Lowell, US
★★★★★ 5
Fits with my Sergand pen!
These fit perfectly with my Sergand pen! Best price I could find on Amazon! I use on my face and they make for a perfect at home microneedling.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 22, 2026
N
Verified Purchase
Nikki lee stippick
Alexandria, US
★★★★★ 5
36 pin micro needle cartridges.
My favorite microneedling cartridges. They are reliable and have never let me down.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 30, 2026
A
Verified Purchase
Anayanky
Lexington, US
★★★★★ 5
Excelente
Los amé tal y como recuerdo haberlos comprado
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 12, 2026

recommand products